PowerSelectors
|
|
These products offer a
convenient way to use 12, 24, 36 or 48 Vdc equipment from Extra Low
Voltage mobile electrical systems of between 12 and 48Vdc. These
cool running products use switch mode technology and are assembled
using surface mount techniques. |
|
| Output Voltage | ||||
| 12 | 24 | 36 | 48 | |
| 12 | PS36i 12-12 | - | PS36s 12-36 |
Not available |
| PS72i 12-12 | PS72s 12-24 | PS72s 12-36 | ||
| PS144i 12-12 | PS144s 12-24 | PS144s 12-36 | ||
| PS288i 12-12 | PS288s 12-24 | PS288s 12-36 | ||
| 24 |
See the PowerVerter range of ten products |
PS36i 24-24 | PS36s 24-36 |
Not available |
| PS72i 24-24 | PS72s 24-36 | |||
| PS144i 24-24 | PS144s 24-36 | |||
| PS288i 24-24 | PS288s 24-36 | |||
| 36 | PS36s 36-12 | PS36s 36-24 | PS36i 36-36 |
Not available |
| PS72s 36-12 | PS72s 36-24 | PS72i 36-36 | ||
| PS144s 36-12 | PS144s 36-24 | PS144i 36-36 | ||
| PS288s 36-12 | PS288s 36-24 | PS288i 36-36 | ||
| 48 | PS36s 48-12 | PS36s 48-24 | PS36s 48-36 | PS36i 48-48 |
| PS72s 48-12 | PS72s 48-24 | PS72s 48-36 | PS72i 48-48 | |
| PS144s 48-12 | PS144s 48-24 | PS144s 48-36 | PS144i 48-48 | |
| PS288s 48-12 | PS288s 48-24 | PS288s 48-36 | PS288i 48 | |
| The product code indicates the output power. |
| The products in yellow have the suffix i and are isolated products. |
To calculate the output current, divide the first number in the product code by the nominal output voltage (12, 24, 36, 48 Vdc)
|
|
Technical Data Dimensions |
| Model | Size | Weight |
| PS36s | 66x87x50mm | 256g |
| PS36i, PS72s | 88x87x50mm | 318g |
| PS72i, PS144s | 126x87x50mm | 455g |
| PS144i, PS288s | 166x87x50mm | 610g |
| PS288i | 216x87x50mm | 750g |
Common Characteristics |
||
| Input Voltage Range | 12 Vdc, 24 Vdc, 36 Vdc, or 48 Vdc, +/-30% | |
| Transient Voltage Protection | Meets ISO7637-2 International Standard for 24Vdc Commercial Vehicles | |
| Electro Static Voltage Protection | Meets ISO10605, ISO14892, >8kV contact, 15kV discharge | |
| Output Voltage Options | 13.6 Vdc, 27.2 Vdc, 40.8 Vdc or 54.4 Vdc. Worst case limits are +15% and -20% | |
| Output Noise | <50mV pk-pk at continuous load. Meets CISPR25 and VDE0879-3 | |
| Intermittent Output power | Continuous rating +25%, taken for a maximum of 2 minutes followed by 8 minutes rest | |
| Off Load Current | <50mA | |
| Power Conversion Efficiency | Typically: 85% for isolated units, 90% for non-isolated units | |
| Isolation | >400Vrms between input, output and case, on isolated products only | |
| Mean Time Between Failures | >162 years (HRD4) | |
| Operating Temperature | -25°C to +30°C to meet this specification table+30°C to +80°C de-rate linearly to 0A | |
| Storage Temperature | -25°C to 100°C | |
| Operating Humidity | 95% max, non condensing | |
| Casework | Anodised Aluminium, Glass Filled PolycarbonateDust water and impact resistance IP533 | |
| Connections | Four 6.3mm push-on connectors | |
| Output Indicator | Red LED adjacent to the output terminals | |
| Mounting Method | Click 'n Fit Mounting clip, fitted separately using three hole fixing | |
| Safe Area Protection | ||
| Over Current | Limited by current sensing circuit | |
| Over Heat | Limited by temperature sensing circuit | |
| Transients | Protected by filters and rugged component selection | |
| Catastrophic failure | Protected by internal input and output fuses | |
| Tested to | ISO7637, ISO10605, ISO14892, ISO14893, ISO11451, ISO11452, CISPR 25, VDE0879-3, EN60945 Annex A | |
| Markings | All are "CE" marked, where appropriate they are "e" marked t | |
|
|